Search results for "Limits of agreement"

showing 10 items of 21 documents

A meta-analysis of the validity of FFQ targeted to adolescents.

2015

AbstractObjectiveThe present work is aimed at meta-analysing validity studies of FFQ for adolescents, to investigate their overall accuracy and variables that can affect it negatively.DesignA meta-analysis of sixteen original articles was performed within the ASSO Project (Adolescents and Surveillance System in the Obesity prevention).SettingThe articles assessed the validity of FFQ for adolescents, compared with food records or 24 h recalls, with regard to energy and nutrient intakes.SubjectsPearson’s or Spearman’s correlation coefficients, means/standard deviations, kappa agreement, percentiles and mean differences/limits of agreement (Bland–Altman method) were extracted. Pooled estimates…

0301 basic medicinePercentileAdolescentDatabases FactualMedicine (miscellaneous)Subgroup analysisFFQDiet SurveysStandard deviationValidityCorrelation03 medical and health sciencesStatisticsNutrition and DieteticHumansMeta-analysiObesityMathematicsObesity prevention030109 nutrition & dieteticsNutrition and DieteticsLimits of agreementPublic Health Environmental and Occupational HealthReproducibility of ResultsResearch PapersMeta-analysisMental RecallEnergy IntakeKappaPublic health nutrition
researchProduct

Current Predictive Resting Metabolic Rate Equations Are Not Sufficient to Determine Proper Resting Energy Expenditure in Olympic Young Adult National…

2021

Predictive resting metabolic rate (RMR) equations are widely used to determine athletes’ resting energy expenditure (REE). However, it remains unclear whether these predictive RMR equations accurately predict REE in the athletic populations. The purpose of the study was to compare 12 prediction equations (Harris-Benedict, Mifflin, Schofield, Cunningham, Owen, Liu’s, De Lorenzo) with measured RMR in Turkish national team athletes and sedentary controls. A total of 97 participants, 49 athletes (24 females, 25 males), and 48 sedentary (28 females, 20 males), were recruited from Turkey National Olympic Teams at the Ministry of Youth and Sports. RMR was measured using a Fitmate GS (Cosmed, Italy…

11035 Institute of General Practice0301 basic medicinePhysiology610 Medicine & healthMeasured RMRlcsh:Physiologypredictive equations03 medical and health sciences2737 Physiology (medical)0302 clinical medicineTotal energy expenditurePhysiology (medical)olympic athletesMedicineResting energy expenditureYoung adultresting metabolic rateOriginal Researchindirect calorimetry030109 nutrition & dieteticslcsh:QP1-981biologyAthletesbusiness.industryLimits of agreement1314 Physiology030229 sport sciencesbiology.organism_classificationlow energy availabilityBasal metabolic rateChristian ministrybusinessDemographyFrontiers in Physiology
researchProduct

Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Glaucoma Patients and Healthy Subjects

2006

To investigate the agreement in the measurement of intraocular pressure (IOP) obtained by dynamic contour tonometry PASCAL (DCT-PASCAL) and Goldmann applanation tonometry (GAT) in glaucoma eyes and healthy eyes with different central corneal thickness (CCT).Prospective cross-sectional study.In a randomized order, three consecutive IOP measurements were performed on 197 eyes of 107 subjects by one examiner using both DCT-PASCAL and GAT on all eyes. Furthermore, ultrasonic pachymetry was performed. The Spearman correlation coefficient (r) was determined to compare IOP readings between DCT-PASCAL and GAT. Regression-based Bland and Altman analysis was used to evaluate agreement between the ins…

AdultMaleApplanation tonometryIntraocular pressuremedicine.medical_specialtygenetic structuresEye diseaseVisual AcuityGlaucomaGoldmann applanation tonometryCorneaTonometry OcularOphthalmologyHumansMedicineProspective StudiesIntraocular PressureAgedUltrasonographyAged 80 and overbusiness.industryLimits of agreementHealthy subjectsReproducibility of ResultsGlaucomaMiddle Agedmedicine.diseaseeye diseasesOphthalmologyCross-Sectional StudiesVisual Field TestsFemaleOcular Hypertensionsense organsbusinessAmerican Journal of Ophthalmology
researchProduct

Automatic algorithm for monitoring systolic pressure variation and difference in pulse pressure.

2009

BACKGROUND: Difference in pulse pressure (dPP) reliably predicts fluid responsiveness in patients. We have developed a respiratory variation (RV) monitoring device (RV monitor), which continuously records both airway pressure and arterial blood pressure (ABP). We compared the RV monitor measurements with manual dPP measurements. METHODS: ABP and airway pressure (PAW) from 24 patients were recorded. Data were fed to the RV monitor to calculate dPP and systolic pressure variation in two different ways: (a) considering both ABP and PAW (RV algorithm) and (b) ABP only (RV(slim) algorithm). Additionally, ABP and PAW were recorded intraoperatively in 10-min intervals for later calculation of dPP …

AdultMaleFluid responsivenessBlood PressureAutomationMonitoring IntraoperativeAbdomenMedicineHumansIn patientPulseAgedObserver VariationBlood Volumebusiness.industryAirway ResistanceLimits of agreementReproducibility of ResultsMiddle AgedReference StandardsPulse pressureAnesthesiology and Pain MedicineBlood pressureData Interpretation StatisticalRespiratory MechanicsFemalebusinessAlgorithmAlgorithmsAnesthesia and analgesia
researchProduct

Jump Height from Inertial Recordings : A Tutorial for a Sports Scientist

2019

Jump performance provides meaningful information both for sporting and clinical needs. Current state-of-the-art in jump performance assessment is laboratory-bound, however, out-of-the-laboratory methods are desirable. Therefore, the purposes of the present investigation were 1) to explore whether utilising a novel analytical approach minimises the bias between inertial recording unit (IMU)-based and jump mat-based jump height estimates, and 2) to provide a thorough tutorial for a sport scientist (see appendix) to facilitate standardisation of jump height estimation. Forty one women, men and boys aged 6 to 77 years-of-age completed three maximal counter movement jumps without arm swing, whic…

AdultMalegyroscopeInertial frame of referenceCorrelation coefficientAdolescentMovementPhysical Therapy Sports Therapy and Rehabilitation030204 cardiovascular system & hematologyAccelerometerwearablelaw.invention03 medical and health sciencesWearable Electronic DevicesYoung Adult0302 clinical medicineInertial measurement unitlawAccelerometryHumansOrthopedics and Sports MedicineliikeanalyysiChildsignal processingSimulationMathematicsAgedinertial measurement unitLimits of agreementGyroscope030229 sport sciencesMiddle AgedBiomechanical PhenomenamittausmenetelmätaccelerometerArm swingJumpExercise TestFemalehyppääminenperformance
researchProduct

Ventilatory threshold during incremental running can be estimated using EMG shorts

2012

The present study examined whether shorts with textile electromyographic (EMG) electrodes can be used to detect second ventilatory threshold (V(T2)) during incremental treadmill running. Thirteen recreationally active (REC) and eight endurance athletes were measured for EMG, heart rate, blood lactate and respiratory gases during VO(2max) test (3 min ramps, 1 km·h(-1) increments). V(T)(2), onset of blood lactate accumulation (OBLA) and EMG threshold (EMG(T)) were determined. In athletes, OBLA occurred at 56 ± 6 mL·kg(-1)·min(-1), V(T2) occurred at 59 ± 6 mL·kg(-1)·min(-1), and EMG(T) at 62 ± 6 mL·kg(-1)·min(-1) without significant differences between methods (analysis of variance: ANOVA). In…

AdultMalemedicine.medical_specialtyAnaerobic ThresholdPhysiologyLactic acid bloodBiomedical EngineeringBiophysicsRunningTreadmill runningPhysiology (medical)Internal medicineHeart rateBlood lactateHumansMedicineLactic AcidElectromyographybusiness.industryLimits of agreementAthletesPhysical EnduranceCardiologyPhysical therapyPulmonary VentilationVentilatory thresholdbusinessPhysiological Measurement
researchProduct

Non‐invasive haemoglobin measurement as an index test to detect pre‐operative anaemia in elective surgery patients – a prospective study

2020

Non-invasive haemoglobin measurement using absolute values lacks the precision to be the sole basis for the treatment of pre-operative anaemia. However, it can possibly serve as a screening test, indexing 'anaemia' with high sensitivity when values remain under prespecified cut-off values. Based on previous data, non-invasive haemoglobin cut-off values (146 g.l-1 for women and 152 g.l-1 for men) detect true anaemia with 99% sensitivity. An index test with these prespecified cut-off values was verified by prospective measurement of non-invasive and invasive haemoglobin pre-operatively in elective surgical patients. In 809 patients, this showed an estimated sensitivity (95%CI) of 98.9% (94.1-…

AdultMalemedicine.medical_specialtyHaemoglobin levelsSensitivity and SpecificityHemoglobins03 medical and health sciences0302 clinical medicine030202 anesthesiologyInternal medicinePreoperative CareHumansMedicineProspective Studies030212 general & internal medicineElective surgeryProspective cohort studyAgedHematologic Testsbusiness.industryNon invasiveLimits of agreementIndex testAnemiaMiddle AgedPre operativeAnesthesiology and Pain MedicineElective Surgical ProceduresFemalebusinessSurgical patientsAnaesthesia
researchProduct

Assessment of Kinect V2 for elbow range of motion estimation in people with haemophilia using an angle correction model

2018

Introduction The joint range of motion (ROM) is an important clinical parameter used to assess the loss of functionality resulting from joint bleedings in people with haemophilia. These episodes require a close follow-up and, to decrease patients' hospital dependence, telemedicine tools are needed. Therefore, this study is aimed to analyse the validity of the Microsoft Kinect V2 sensor with corrected angle measurement to be used in the monitoring of elbow ROM in people with haemophilia. Methods A convenience sample of 10 healthy controls (CG) and 10 patients with haemophilia with elbow arthropathy (HG) participated in this study. Full ROM of elbow joints was measured in the frontal view wit…

AdultMalemedicine.medical_specialtyWilcoxon signed-rank testElbow030204 cardiovascular system & hematologyHemophilia AHaemophiliarange of motion03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationElbow JointHemarthrosisArthropathymedicineElbow jointsupper extremityHumansRange of Motion ArticularGenetics (clinical)Models Statisticalbusiness.industryLimits of agreementhaemophilic arthropathy3D depth sensorHematologyGeneral Medicinemedicine.diseasemedicine.anatomical_structureGoniometerFemaleRange of motionbusinessgoniometry030215 immunology
researchProduct

Möglichkeiten der 16-Schicht-CT bei der linksventrikulären Funktionsbestimmung: Beurteilung zweier unterschiedlicher Software-Tools zur quantitativen…

2004

PURPOSE To determine global and regional left ventricular (LV) function from retrospectively gated multidetector row computed tomography (CT) by using two different semiautomated analysis tools and to correlate the results with those of magnetic resonance imaging (MRI). MATERIALS AND METHODS Nineteen patients (5 females, 14 males, mean age 69 years) underwent 16-slice spiral-CT (MS-CT) with standard technique without administration of beta-blockers for a decrease in the cardiac rate. Ten series of images were reconstructed at every 10 % of the RR-interval. With commercially available software capable of semiautomated contour detection, end-diastolic and end-systolic LV volumes (EDV and ESV)…

Contrast enhancementShort axisEjection fractionmedicine.diagnostic_testbusiness.industryLimits of agreementMagnetic resonance imagingStroke volumeStandard techniquemedicine.anatomical_structureVentricleMedicineRadiology Nuclear Medicine and imagingbusinessNuclear medicineRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Agreement of predicted intraocular lens power using swept-source optical coherence tomography and partial coherence interferometry

2021

PURPOSE To analyze the agreement of the predicted intraocular lens (IOL) power obtained with ANTERION, IOLMaster 700 and Pentacam AXL biometers. METHODS We calculated the monofocal and trifocal IOL power using the SRK/T, Haigis, Barrett Universal II and Hoffer Q formulas for 106 eyes. IOL power agreement between devices was evaluated using the Bland-Altman method. RESULTS We found significant differences between biometers comparisons (p  0.05), with the same outcomes for medium- and long-eyes. No significant differences were found using the SRK/T, Haigis, or Hoffer Q formulas for short-eyes (p > 0.1). However, Barrett Universal II formula produced significant differences (p < 0.05) and thes…

Lenses IntraocularPhysicsmedicine.medical_specialtyBiometrymedicine.diagnostic_testmedicine.medical_treatmentLimits of agreementScheimpflug principleBiomedical EngineeringReproducibility of ResultsIntraocular lensGeneral MedicineAxial Length EyeInterferometryOptical coherence tomographyIntraocular lens powerPartial coherence interferometryOphthalmologymedicineHumansOptical biometerSurgeryTomography Optical CoherenceRetrospective StudiesExpert Review of Medical Devices
researchProduct